Printer FriendlyEmail Article Link

Positioning Application: How do I assign PRN 37 to a GALILEO SVID in the Single Channel Utility

Environment/Versions
  • PosApp v8.00 onwards
  • SimGEN
  • SimREPLAYplus
  • SimTEST
  • Single Channel Utility (SCU)
Answer
  • Post PosApp v8.00, PRN 1 - 36 was only supported in the Single Channel Utility
  • To select a PRN number greater than 36
    1. Under the scenario tree, locate Antenna ⇒ Initial state
    2. With GALILEO selected, enter the desired PRN number. The increased maximum value is now 50.
  • SimGEN, SimREPLAYplus and SimTEST also support the increased PRN maximum figure
    1. In the scenario tree, open the GALILEO Signal Sources file
    2. Navigate to Signal control ⇒ General
    3. Enter the desired PRN number for that SVID, up to a maximum value of 50 

Product : SimREPLAYplus,SimGEN,PosApp,SimSCU,SimTEST