Spirent TestCenter: RSVP crashes when Head-End router updates the min-BW
Symptoms
The tunnels are initially signaled correctly with configured
min-bandwidth
and the tunnels remain stable.
Once a given set of
RSVP/TE
tunnels receives traffic and the
Head-End
router updates the min-bandwidth, it leads to some problems on the Spirent side.
Tunnel signaling breaks and the
RSVP
process gets stopped.
Environment
Spirent TestCetner 5.30 and older.
RSVP/TE
Explanation/Resolution
The issue occurred because while raising the events, STC will not make sure all of the data structures are valid.
In some rare cases, as there were no safety checks in the code, it leads to a crash.
The fix to this issue is available in STC GA's starting in version 5.31.
Root Cause
The crash happens basically due to
access violation
and
segmentation fault
.