Spirent TestCenter : How to verify Data Integrity check function?

Environment/Versions
  • Spirent TestCenter
  • Traffic Analyzer
Answer

This could be done in different ways

  • Set the frame payload fill to PRBS
    Analyze the received PRBS error counters per port or streamblock to measure the ratio of data corruption by DUT.
  • Turn off the Spirent signature and set the payload to all "A"s.
    Analyze and see if all "A"s are received via capture at receiving port.
  • If the frame sizes are small enough, use triggers or Analyzer filters to check RX data
  • Add a TCP or UDP header and monitor their checksum.