Positioning Application, SimCHAN: The software reports "Error: Cannot arm scenario", "Error:... problems with the signal generator hardware", "Error:... unit is not licenced for this PC"
Environment/Versions
PosApp (SimGEN / SimREPLAYplus / SimREPLAY)
SimCHAN v3-02 or later
Answer
After trying to start the scenario the following sequence of error messages are displayed (and/or written to the Message Log file)
Note that the serial number given in Figure 3 is an example only and will change based on the system in use
This is caused by a missing or incorrect "Hardware Key" for the
Auxlliary
unit(s) connected in the system
If you are using a version of SimGEN / SimREPLAYplus / SimREPLAY before v2-90, see Note 2 below
To resolve the error follow these steps:-
Exit the software
Go to the software root directory
- For PosApp = C:\Program Files\Spirent Communications\Positioning Application
- For SimCHAN = C:\Program Files\Spirent Communications\SimCHAN
Locate the utility = "hardware_keys_utility.exe"
Launch the utility
Use the "Customer Specific Files" CD, supplied with the original shipment, to
- Check that any entered keys match the ones for your Auxillary units
- Add keys that are missing
If you cannot locate the "Customer Specific Files" CD or the problem still occurs when you enter keys provided on the CD, please refer to the information below to contact Spirent Global Services
NOTES
Hardware Keys are installed by Spirent at the time of configuring the host PC controller (if Spirent provide the PC). The main reaons why keys will be missing are:-
- Spirent did not provide the host PC and the user has overlooked this requirement during their own set-up procedure
- A replacement or additional PC has been configured for use with the simulators and the keys have not been entered during that procedure
- New Auxilliary units have been provided for integration with an existing Master unit and keys have not been entered on to the original host PC controller
Before PosApp v2-90 Hardware Keys were also used for the Master unit too. Users with these earlier software versions will need to ensure they have keys for all simulators.
From PosApp v2-90 and SimCHAN v3-00 a the licence file, "lservrc.txt", authenticates the software to work with the
Master
simulator.
- When just one simulator is used the licence file is all you need.
- When there are two or more simulators in the system, the licence file authenticates the Master and the Hardware Key(s) authenticate the Auxillary unit(s)
CONTACT SPIRENT GLOBAL SERVICES
Use the "Submit a Service Request" link on the right hand side of the Knowledge Base screen
Summarise the issue (reported error messages) and what fault finding steps have already been taken
Confirm the software version that is being used
- Take a screenshot of menu [Help-->About]
Go to the software root directory and provide copies of the following files
- "sig_gen.txt"
- "lservrc.txt"