There are two ways to generate simultaneous call in Abacus. They are:
1. By configuring the SS, CL, IC and CC timing in the Partition & Timing window.
2. Use of the Load Profile: Call Volume.
Method 1 would require a careful calculation of number of channels, call holding time and other factors. Furthermore, the actual calling may drift over time, depending on the network situation. Method 2 is more user friendly to configure and the system will adjust the actual call generation based on the current network situation. For this reason, users are recommended to use method 2.