Printer FriendlyEmail Article Link

Spirent TestCenter: Why Spirent TestCenter permanent license does not work in third test card?

Environment/Versions
 
  • Spirent TestCenter
  • Licensing
  • License Check
  • 0001_PACKET_GEN_ANALYZER_BPK_A License


The issue could exists in a specific situation. Let say the STC could be a SPT-11U (obsolete chassis by now - January 2020), SPT-N11U or SPT-N12U, and there are five test cards in the chassis (any card number >2), and the all permanent licenses have been succesfully installed.

The first two cards can be used to test. In the meanwhile, if test with the rest cards (all at the same time), there will be an error message showing the license is missing:
License Check: Failed to validate 0001_PACKET_GEN_ANALYZER_BPK_A
License Check: Chassis missing valid “0001_PACKET_GEN_ANALYZER_BPK_A” License.
 
 

Actually, the permanent license is right there.
 
 
enlightenedIn case you noticed that 0001_PACKET_GEN_ANALYZER_BPK_A version date could be "out-to-date", be aware the version date under SPIRENT SOFTWARE ENTITLEMENT "overwrites" it.
 
Answer

 

  • The issue could be due to the license is 2PK MOD which it enables only 2 supported modules in chassis.
    • This could be caused more likely because originally the license was initially from an N4U chassis (2 modules only) and after upgrading to a N11U/N12 chassis the license has been transferred to these new chassis.
      • For those upgrade the license should have ben upgraded to support the whole N11U/N12U cards - You can reach the sales team to get help about this particular behavior.
 
How can I validate if the license is 2PK MOD?
 
  • You can check the .lic file, search for STYPE under PACKET_GEN_ANALYZER_BPK_A section:
INCREMENT 0001_PACKET_GEN_ANALYZER_BPK_A spirentd 2015.05 permanent \
uncounted VENDOR_STRING="NAME=PACKET GENERATOR AND ANALYZER \
BASE PACKAGE A;PN=BPK-1001A;ILTYPE=;STYPE=2;LICTYPE=PERMANENT" \
HOSTID=VDH=E15051188 START=1-may-2015 TS_OK SIGN="0024 6CFA \
C7D7 3ED2 CE31 DFF3 01BF 0200 6225 A307 C6F4 D744 82B1 9E53 \
61C0"

STYPE=2 
enables only 2 supported modules in chassis.
 
  • Our Front Line team could also help you to validate it.
    • Example of 2PK MOD license types are (just for reference):
      • SPK-0005-2XMOD (STC)
      • BPK-1218A-2XMOD (AVALANCHE)
      • BPK-1200A-2XMOD (AVALANCE)
 

Workaround:
 

  • enlightenedNOTE: This workaround ONLY works If you find two "0001_PACKET_GEN_ANALYZER_BPK_A" licenses within the .lic file as below:

The STYPE of the first one is 2.

INCREMENT 0001_PACKET_GEN_ANALYZER_BPK_A spirentd 2011.09 permanent \
 uncounted \
 VENDOR_STRING=NAME=;PN=;ILTYPE=;STYPE=2;LICTYPE=PERMANENT \
 HOSTID=VDH=E11370910 START=30-sep-2011 TS_OK SIGN="0056 63F0 \
 6ACA CD5C F1F1 022C EAF1 6300 A595 8C31 AAE5 817E CDC3 F957 \
 F70C"

The STYPE of the other is null.

INCREMENT 0001_PACKET_GEN_ANALYZER_BPK_A spirentd 2011.09 permanent \
 uncounted VENDOR_STRING="NAME=PACKET GENERATOR AND ANALYZER \
 BASE PACKAGE A;PN=BPK-1001A;ILTYPE=;STYPE=;LICTYPE=PERMANENT" \
 HOSTID=VDH=E11370910 START=30-sep-2011 TS_OK SIGN="0081 9397 \
 001C 5DC5 CCB8 EAAD 0906 D500 8FC5 D7C6 56A5 3A42 573C F03B \
 7ED7"


Just delete the first “0001_PACKET_GEN_ANALYZER_BPK_A” license which STYPE is 2.
 



Product : Spirent TestCenter,License Issues