How to set up and run Spirent TestCenter RFC2544 test case with different Upstream and downstream loads?

Answer

Symmetric RFC2544 does not support different load for upstream and downstream and always run with same load per iteration

Spirent TestCenter Asymmetric RFC2544 wizard should be used to set up a testcase with different loads upstream & downstream

Please note, prior to v4.15, when using a large number of ports to run the Asymmetric tests, saving the results for each iteration may take an abnormally long time.


Product : Spirent TestCenter,General Navigation,Spirent TestCenter