Printer FriendlyEmail Article Link

Spirent TestCenter: How is the delay measurement calculated in EOAM/Y.1731 DMM?

Environment/Versions
  • Spirent TestCenter
  • EOAM/Y.1731
  • Carrier Ethernet
Answer
  • Round Trip time = (RxTimeb–TxTimeStampf)
  • Round Trip Transmission time = (RxTimeb–TxTimeStampf)–(TxTimeStampb–RxTimeStampf)
  • DUT processing time = (TxTimeStampb–RxTimeStampf)
     

Note that people miss the Round Trip Transmission time in the GUI because they have to scroll further to the right.



You may need to set the common time source.


Product : Spirent TestCenter,Data Center,Spirent TestCenter,EOAM