Positioning Application: What specifies the GLONASS reference time in the UDD file when using the Rinex Parser?

Environment/Versions
  • PosApp V4.03 SR01 onwards
  • Rinex Parser (more info in FAQ14528)
  • Rinex V2.10 only
Answer
  • The GLONASS reference time in the record header of the UDD file is populated for each SV based on the time in the RINEX file used.
    • The example below demonstrates how SV 1 and SV 7 have taken the reference time from the RINEX file used

 