Printer FriendlyEmail Article Link

Spirent TestCenter: Why is Spirent TestCenter giving me an ERROR message “Stream block (StreamBlock Name): Invalid input parameters: No more available fast stream indexes.”

Environment/Versions
  • Spirent TestCenter
  • 4.36 Version
Answer
  • The Following Error occurs when configuring StreamBlock on DX-10G-32 card:

Rpc manager received errors; 2 error msgs  SeqNum 31921 Msgr port //X.X.X.X/5/1 req Generator_3.SetStreamBlock code -10001 faultMsg Stream block (StreamBlock Name): Invalid input parameters: No more available fast stream indexes.

To avoid this Error, uncheck “High Speed Result Analysis” on streamblock


 

  • The same validation error is observed for MX-100G-F2 card because of more scale. By disabling "HSRA" or by scaling back the test the error is not seen.

Product : DX,MX,Spirent TestCenter,Windows GUI,Spirent TestCenter