PosApp: Can the state of an Interference Signal Generator (Agilent, GSS7765) be displayed in PosApp?
Environment/Versions
PosApp v7.01 onwards
SimGEN
GSS9000
GSS8000
Agilent "GSS7765" Interference Signal Generator (ISG)
Answer
Yes, from PosApp v7.01 the status of an Agilent "GSS7765" Interference Signal Generator (ISG) can be read from PosApp's
System Messages
window and the log files
PosApp checks the status of the ISG at regular intervals. If the response from the ISG indicates a problem (anything except +0,"No error"), PosApp reports the response as follows:
If the scenario is running, PosApp reports the response as "
Error
" and the scenario continues running
If the scenario is not running, PosApp reports the response as "
Fatal
" and the scenario cannot be started until the ISG problem is resolved