Spirent TestCenter: How can I do a basic IPv4 configuration?
Environment/Versions
Spirent TestCenter.
IPv4.
Topology.
Answer
Open the
Spirent TestCenter Application
, connect to a chassis, and reserve 2 ports.
Go to
All Devices
and hit the
Add
button.
Select
IPv4
in the
Select Encapsulation
screen.
After you finished the
Add Devices
wizard, set the emulated devices' IPv4 configuration to match your testbed. In this case, it should be:
Device 1.
IP address
10.10.10.4
Default Gateway
10.10.10.2
Device 2.
IP address
10.10.10.3
Default Gateway
10.10.10.1
Go to
All Stream Blocks
and hit the
Add
button.
Select
Device 1
under
port 10/1
as the source port.
Select
Device 2
under
port 10/2
as the destination port.
If you want traffic to be bidirectional enable it under
Orientation
.
Hit the
Add
button.