Customer Service Center
Home
Knowledge Base
Contact Support
License Activation
|
Contact Support
|
License Activation
|
Spirent KB Article
Doc ID: FAQ20310
Printer Friendly
Email Article Link
Spirent TestCenter:TCIQ How to use Port List / Port Map in order for them to be populated when generating a report
Environment/Versions
STC all versions
TCIQ browser
Answer
In order to populate these 2 specific colums, there are a few restrictions:
1) Port List:
- Port list only supports sequencer based tests
- Port list is populated only when all of the below “filters” are active at the same time:
configured streamblock is set as != Pair
used in the sequencer
sequencer has iterations configured
stream frames are not showing up on unexpected ports (not flooded)
For example, RFC2544 Throughput test:
Result after generating the report:
2) Port Map:
- same information needs to be active as above
- only thing that changes here is configured streamblock is set as
==
Pair
Version
4.0
Publish Date
2023-08-03