Spirent TestCenter: Why does the GUI show ports going out of sync?
Answer
When the chassis is using an external clock source such as CDMA to sync multiple chassis together, a port may try to re-sync if the CDMA unit reports it lost its time source.
Previously ports would try to re-sync even if someone is using the chassis. V3.60 has been updated to wait for the chassis to not be in use before re-sync occurs. Note that if the external clock source has not re-acquired its time source after 30 minutes the chassis will revert back to an internal clock.