Printer FriendlyEmail Article Link

How do I configure the MME Nodal Test Case to restart the S1-AP and NAS layers upon SCTP link recovery on Landslide?

Answer

The "Restart on SCTP Link Recovery" option was added to the MME Nodal Capacity Test Activity only, S1-MME>SCTP tab to support restarting of upper layer applications (S1 setup/NAS attach) upon SCTP link recovery. Please verify that the option is enabled as shown below.

Also see attach document for call flow where this feature apply to.

 


Product : Landslide Client,Landslide,S1