Customer Service Center
Home
Knowledge Base
Contact Support
License Activation
|
Contact Support
|
License Activation
|
Spirent KB Article
Doc ID: FAQ13981
Printer Friendly
Email Article Link
Spirent TestCenter: is it possible to run random load or rate on C1 10G chassis with NIC-27?
Environment/Versions
When the customer tries to Apply to run random load or rate traffic on C1 10G chassis they receive error message:
Error Other ResultDataSetSubscribeCommand 2 failed with error: Rpc manager received errors; 1 error msgs SeqNum 60 Msgr port //XX.XX.XX.XX/1/1 req Generator_X.SetCommonCfg code -10001 faultMsg Invalid input parameters: The test module currently cannot support random port rate.
Answer
No it is not possible to run random load or rate on C1 10G chassis , the NIC-27 has that limitation as its Generator implementation is based on the DX-10G-S32 test module.
Version
4.0
Publish Date
2016-02-15
Categories
Product : Spirent TestCenter,PGA
Related Articles