Printer FriendlyEmail Article Link

Vision Works Probe: Getting “CIR EXCEEDS LIMIT. RETRY LATER” error message when attempting an access on a VisionWorks Probe.

Environment/Versions
7502 all versions
7521
7522
7531
7561
Answer
When you get this error message, do the following:
  • Verify the probe has the TOTALCIR and TOTALKFPS setting set correctly.  Follow FAQ18026.
If correct:
  • Find the comm log for the test that got the error message.
-or-
  • Telnet into the probe on port 7010.
  • If you telnet into the probe, issue : 
    • act-user::super:ctag::super
    • rtrv-cond-tst:::ctag
 
Now, add up all the CIRs for all the entries.  Remember that the TOTALCIR listed in RTRV-ATTR-EQPT output is across all ports and tests.  So, if you have a 7531 with a TOTALCIR=1000 and you have a 900mbs test on port 1, you will only be able to test up to 100mbs on port 2.
 
In the following example of a 7521 (10G), 1180mbs are already taken up leaving 8820mbs available for any type of test on either port.

 
   BRDVILBO-MOD1-QSCOPE 19-01-07 21:46:10
M  EDR COMPLD
   /* SPIRENT COMMUNICATIONS OF ROCKVILLE - COPYRIGHT (C) 2009-2017              */
   /* TSN PORT VLAN      PRI SRC_IP          CIR       KFPS  DES_ADDR            */
   /*                                       STATUS                     TYPE      */
   "  504 1                             150.0     517     "
   "                                        TST-ETHDM-Y1731-PM                    "
   "  635 2                             150.0     497     "
   "                                        TST-SLA                               "
   "  308 1                  10.187.4.5  150.0     27      "
   "                                        TST-TWAMP-PM                          "
   "  3   1    2278          10.187.4.3  20.0      47      "
   "                                        START-ADDR-LPBK                       "
   "  2   2    1671          10.233.1.174  20.0      47      "
   "                                        START-ADDR-LPBK                       "
   "  1   1    1670          10.233.1.170  20.0      47      "
   "                                        START-ADDR-LPBK                       "
   "  6   2    2279          10.187.4.20  100.0     280     "
   "                                        START-TWAMP-SERVER                    "
   "  5   1    2278          10.187.4.4  100.0     280     "
   "                                        START-TWAMP-SERVER                    "
   "  4   2    2279          10.187.4.19  20.0      47      "
   "                                        START-ADDR-LPBK                       "
   "  556 2                             150.0     509     "
   "                                        TST-ETHDM-Y1731-PM                    "
   "  616 2                  10.187.4.21  150.0     27      "
   "                                        TST-TWAMP-PM                          "
   "  585 1                             150.0     502     "
   "                                        TST-SLA 
 

Product : VW Controller T&D Classic,VisionWorks Probe