Spirent TestCenter: How to configure FCoE on STC using two B2B ports?
Environment/Versions
STC
FCoE
Answer
Open the GUI and connect to your chassis.
Create 4 devices, 2 on each port. The devices you're going to create may have checked the
None
option for the
Protocol Technologies
and
Upper Layer
options.
It's recommended to name the devices as
VN_PortX
and
VF_PortX
or something that will help you to identify them.
Add the
FCoE
to the encapsulation of every device. To do this, click on any of the cells under the
Encapsulation
column and then on the square with the ellipsis.
Modify the
World Wide Port Name
so that each device has a different value.
Set to
Active
both of the devices that will work as
VN
. You will find this option under the
FCoE VN_Port
tab.
Modify the
FC Map
value in one of the devices, so that it won't match the value on the other device.
Set to
Active
both of the
VF
devices. You will find this option under the
FCoE VF_Port
tab.
Modify the
FC Map
value in one of the devices. The
VN_Port FC Map
on
Device 1
should match with the
VF_Port FC Map
on
Device 2
.
After that, on the
FCoE VF_Port
tab, highlight the VF devices, right-click over one of them, and go to
FCoE VF_Port > Start FCoE VF_Port
.
After that, the
Aggregate Sub State
will go into
PLOGI Accepted;
this means that you have
FCoE
running.
Once you have configured this, you can create your stream blocks and run traffic. It's important to mention that the stream blocks need to be configured between the
VN_Ports.
Version
6.0
Publish Date
2022-06-23
Categories
Product : Spirent TestCenter,FCoE