Customer Service Center
Home
Knowledge Base
Contact Support
License Activation
|
Contact Support
|
License Activation
|
Spirent KB Article
Doc ID: FAQ18959
Printer Friendly
Email Article Link
TTworkbench: why is the payload of ETS message from the test system is longer than the length value in the message?
Environment/Versions
TTsuite-OPEN-SomeIP
The message is constructed based on Ethernet.
If the message to send it shorter than 60 bytes, it will be padded to 60 bytes before sending. The mininal length of Ethernet frame must be 64 bytes, which consists of
Dest-MAC-Address = 6,
Src-MAC-Address = 6,
Frametype = 2,
Data >= 46
FCS = 4
Total = 64
Please refer to the following articles
https://networkengineering.stackexchange.com/questions/34189/minimum-ethernet-frame-is-64-bytes-why-the-payload-must-be-padded-to-at-least-4
The DUT should be able to recognize the real length of payload according to the length value in the message.
Version
1.0
Publish Date
2019-11-04