Spirent TestCenter: How to configure BGP LU on Spirent TestCenter?
Environment/Versions
Spirent TestCenter
BGP LU (Labeled Unicast)
Answer
Open Spirent TestCenter Application.
Connect to a chassis and reserve the ports.
Configure your devices and enable BGP.
Make sure that the BGP session gets established between your devices.
Add some BGP routes to your configuration.
On Spirent TestCenter Application select
All Devices
at the left tree menu and Select the BGP tab and hit the
Edit Routes
button.
At the
IPv4 Routes
tab set the
SubAFI
as
Labeled IP,
enable the
MPLS Label
and add the labels at the
Custom MPLS Labels
fields.
Now you can configure stream blocks using the generated routes as source/destination.
If you start a capture and after that the traffic, you will see the MPLS labels you configured.