Spirent TestCenter: How can I run an OFDMA test on an C50 Spirent TestCenter Appliance.
Environment/Versions
C50 appliance.
Spirent TestCenter Application.
WiFi
OFDMA.
Answer
To test OFDMA, we need at least 2 WiFi ports on the C50; each port does just one OFDMA capable client. Ideally, you will need four ports from the C50 for 4 OFDMA clients.
With OFDMA enabled, it takes the C50 a bit more time to process the data pass for multi-client purposes, so the best way to run an OFDMA test is to leave it enabled on the C50 side and enable/disable it on the AP.
Refer to:
FAQ19478
- Spirent TestCenter: How can I configure OFDMA and MU-MIMO on Spirent TestCenter?