Spirent TestCenter: Aggregated counters as "Aggregated frame loss duration (us)" are not available in TestCenter IQ
Symptoms
In classic results is possible to get Frame Loss Duration at streamblock level by using DRV (Dymamic Result View) and using Aggregated Frame Loss column as shown below:
These same values do not exist in Enhanced Results 5.07.
Environment
Spirent TestCenter
5.07
Explanation/Resolution
There is not frame loss duration (aggregated) available in 5.07 but it has been added in 5.08.