Spirent TestCenter: PX3 appliance showing Power Failure warning messages.
Symptoms
A
PX3
appliance is showing Power Failure warnings constantly. Please refer to the images below:
Environment
Mantis and Groot appliances running STC firmwares releases 5.34 and older.
Explanation/Resolution
The solution included:
Supporting clock stretching for devices marked as requiring clock stretching support.
Marking the devices on the PX3 chassis that require clock stretching, and fixing the peripheral daemon to dynamically determine the correct I2C bus numbers.
Root Cause
PX3 appliances didn't had clock stretching support untill 5.35.
Version
1.0
Publish Date
2022-08-03