Symptoms
The customer is seeing the below error after enabling the RFC 8239 test:
Stream block (StreamBlock 280970) Project-level stream block missing endpoint-binding
Environment
Spirent TestCenter
RFC
RFC8239
RFC 8239
8239
Project-level stream block missing endpoint-binding
Explanation/Resolution
Turned out the customer did not have the licenses to run any test in Spirent TestCenter
Root Cause
License misssing