Customer Service Center
Home
Knowledge Base
Contact Support
License Activation
|
Contact Support
|
License Activation
|
Knowledge Browse
Doc ID: FAQ12166
Printer Friendly
Email Article Link
Positioning Application, SimCHAN: When arming/running a scenario what causes the message "Error: switch modes#1 don't match: incorrect signal types" ?
Environment/Versions
PosApp (SimGEN / SimREPLAYplus / SimREPLAY)
GSS6700
SimCHAN v3-00 or later
GSS6300 / GSS6300M
Answer
This above error occurs due to a mismatch between the sig_gen.txt and the signal generator capabilities.
The sig_gen.txt file details are used to enable correct selection of scenario signal types which match the expected simulator capabilities
Only when the scenario is started, during the ARming phase, does the software actually confirm the expected signal capability with the simulator hardware itself
If there is a mismatch the scenario cannot continue into its running phase
In the above example error message
PosApp (running in SimGEN mode), using the sig_gen.txt file, has expected the GSS6700 to have GPS L1 only signal capability
The GSS6700 itself actually has GPS L1 + GLONASS L1 signal capability
The most likely causes for this mismatch is during a system upgrade
The unit has been upgraded with the new feature key but the new sig_gen.txt file has not been copied to the software directory, e.g. C:\Program Files\Spirent Communications\Positioning Application
OR
The new sig_gen.txt file has been copied to the software directory but the unit has not been upgraded with the new feature key / the feature key upgrade failed
If you are having difficulty with your system upgrade please contact Spirent Global Services as follows:-
Open a new Service Request using the 'Submit a Service Request' link on the right-hand side of the Knowledge Base area
Confirm the model number and serial number of the simulator involved
Confirm that you have followed the instructions in
DCS0038B
Provide a screenshot of the 'string send' utility required in DCS0038B, showing all commands and responses that have been sent / received
Provide a copy of the
latest
sig_gen.txt file provided by Spirent
Provide a copy of the feature key you're trying to use and confirm what signal capabilities the feature key is intended to enable
Version
4.0
Publish Date
2014-07-29
Categories
Product : SimCHAN,SimREPLAYplus,SimREPLAY,SimGEN,PosApp,GSS6300,GSS6700,GSS6300M