Printer FriendlyEmail Article Link

Spirent TestCenter: How can I do a basic IPv4 configuration?

Environment/Versions
  • Spirent TestCenter.
  • IPv4.
Topology.
 
Answer
  • Open the Spirent TestCenter Application, connect to a chassis, and reserve 2 ports.
  • Go to All Devices and hit the Add button.
  • Select IPv4 in the Select Encapsulation screen.
  • After you finished the Add Devices wizard, set the emulated devices' IPv4 configuration to match your testbed.  In this case, it should be:
 
Device 1.
IP address        10.10.10.4
Default Gateway   10.10.10.2
 
Device 2.
IP address        10.10.10.3
Default Gateway   10.10.10.1
  • Go to All Stream Blocks and hit the Add button.
  • Select Device 1 under port 10/1 as the source port.
  • Select Device 2 under port 10/2 as the destination port.
  • If you want traffic to be bidirectional enable it under Orientation.
  • Hit the Add button.

Product : Spirent TestCenter