Printer FriendlyEmail Article Link

VisionWorks Classic: How do I gracefully STOP and START the VisionWorks Classic T&D and PM applications

Environment/Versions
For VisionWorks Classic T&D and PM
 
Answer

Graceful shut down:
You must stop VW Classic PM first , then T&D.


Shutdown PM:

PM - Check Status
/spirent/metro/escout/status

STCLPM services Web Server running...
STCLPM cron running
120

Checking to see if the eScout main Collection process is running...
The main Collection process is running...
Number of collections currently occuring:
Number of collections currently occuring:
EOAM      :0
ETHDM     :0
ETHSLM    :0
MCAST-PING:0
MON-PORT  :0
NETQ-IP   :0
NETQ-MAC  :0
PING      :1217
TWAMP     :555
VIDEO     :0
CHILDREN  :1

STCLPM fully running

Stop PM:
01. /spirent/metro/escout/stop -full
02. Check status until All PM collections has stopped before stopping T&D: /spirent/metro/escout/status

--

Shutdown T&D:

T&D - Check Status:
/spirent/metro/<release#>/scripts/statusMetro
Sample output - in this case Failover is not enabled.

PointOfServiceServer is running (pid=33605)
AuditingServer is running (pid=33340)
SecurityServer is running (pid=33475)
MetroEngine is running (pid=34171)
MetroInventory is running (pid=33828)
DeviceControl is running (pid=32715)
MetroUI is running (pid=34401)
Failover Script is not running

Stop T&D:
01. Disable users logins from UI (this prevents users from logging into T&D while shutting down)
02. Stop T&D: /spirent/metro/<release#>/scripts/stopAllMetro
03. Check status until all T&D processes have stopped: /spirent/metro/14.600/scripts/statusMetro

/spirent/metro/<release#>/scripts//statusMetro
PointOfServiceServer is not running
AuditingServer is not running
SecurityServer is not running
MetroEngine is not running
MetroInventory is not running
DeviceControl is not running
MetroUI is currently not running
Failover Script is not running

----

Graceful Startup:
You must start VW Classic T&D first, then PM.


Start T&D:
Make sure Informix is up before starting T&D, check with "onstat -"
=> onstat -
IBM Informix Dynamic Server Version 14.10.FC4W1 -- On-Line -- Up 12 days 17:24:14 -- 3737860 Kbytes

01. Start T&D: /spirent/metro/<release#>/scripts/startAllMetro
02. Check status to see all processes up

/spirent/metro/<release#>/scripts/statusMetro
Sample output - in this case Failover is not enabled.

PointOfServiceServer is running (pid=33605)
AuditingServer is running (pid=33340)
SecurityServer is running (pid=33475)
MetroEngine is running (pid=34171)
MetroInventory is running (pid=33828)
DeviceControl is running (pid=32715)
MetroUI is running (pid=34401)
Failover Script is not running

Start PM:
01. Enable users logins from T&D UI (allows escout user to log into T&D for processing collections when starting PM)
02. Start PM: /spirent/metro/escout/start
03. Check status until All PM collections has started: /spirent/metro/escout/status

/spirent/metro/escout/status
STCLPM services Web Server running...
STCLPM cron running
120

Checking to see if the eScout main Collection process is running...
The main Collection process is running...
Number of collections currently occuring:
Number of collections currently occuring:
EOAM      :0
ETHDM     :0
ETHSLM    :0
MCAST-PING:0
MON-PORT  :0
NETQ-IP   :0
NETQ-MAC  :0
PING      :1217
TWAMP     :555
VIDEO     :0
CHILDREN  :1

STCLPM fully running

--

End of steps - Completed
 


Product : VW Controller PM Classic,VW Controller T&D Classic,Informix