Graceful shut down: You must stop VW Classic PM first , then T&D. Shutdown PM: PM - Check Status /spirent/metro/escout/status STCLPM services Web Server running... STCLPM cron running 120 Checking to see if the eScout main Collection process is running... The main Collection process is running... Number of collections currently occuring: Number of collections currently occuring: EOAM :0 ETHDM :0 ETHSLM :0 MCAST-PING:0 MON-PORT :0 NETQ-IP :0 NETQ-MAC :0 PING :1217 TWAMP :555 VIDEO :0 CHILDREN :1 STCLPM fully running Stop PM: 01. /spirent/metro/escout/stop -full 02. Check status until All PM collections has stopped before stopping T&D: /spirent/metro/escout/status -- Shutdown T&D: T&D - Check Status: /spirent/metro/<release#>/scripts/statusMetro Sample output - in this case Failover is not enabled. PointOfServiceServer is running (pid=33605) AuditingServer is running (pid=33340) SecurityServer is running (pid=33475) MetroEngine is running (pid=34171) MetroInventory is running (pid=33828) DeviceControl is running (pid=32715) MetroUI is running (pid=34401) Failover Script is not running Stop T&D: 01. Disable users logins from UI (this prevents users from logging into T&D while shutting down) 02. Stop T&D: /spirent/metro/<release#>/scripts/stopAllMetro 03. Check status until all T&D processes have stopped: /spirent/metro/14.600/scripts/statusMetro /spirent/metro/<release#>/scripts//statusMetro PointOfServiceServer is not running AuditingServer is not running SecurityServer is not running MetroEngine is not running MetroInventory is not running DeviceControl is not running MetroUI is currently not running Failover Script is not running ---- Graceful Startup: You must start VW Classic T&D first, then PM. Start T&D: Make sure Informix is up before starting T&D, check with "onstat -" => onstat - IBM Informix Dynamic Server Version 14.10.FC4W1 -- On-Line -- Up 12 days 17:24:14 -- 3737860 Kbytes 01. Start T&D: /spirent/metro/<release#>/scripts/startAllMetro 02. Check status to see all processes up /spirent/metro/<release#>/scripts/statusMetro Sample output - in this case Failover is not enabled. PointOfServiceServer is running (pid=33605) AuditingServer is running (pid=33340) SecurityServer is running (pid=33475) MetroEngine is running (pid=34171) MetroInventory is running (pid=33828) DeviceControl is running (pid=32715) MetroUI is running (pid=34401) Failover Script is not running Start PM: 01. Enable users logins from T&D UI (allows escout user to log into T&D for processing collections when starting PM) 02. Start PM: /spirent/metro/escout/start 03. Check status until All PM collections has started: /spirent/metro/escout/status /spirent/metro/escout/status STCLPM services Web Server running... STCLPM cron running 120 Checking to see if the eScout main Collection process is running... The main Collection process is running... Number of collections currently occuring: Number of collections currently occuring: EOAM :0 ETHDM :0 ETHSLM :0 MCAST-PING:0 MON-PORT :0 NETQ-IP :0 NETQ-MAC :0 PING :1217 TWAMP :555 VIDEO :0 CHILDREN :1 STCLPM fully running -- End of steps - Completed