What is the difference between pushing the stop button once or twice in the Avalanche Commander?
Answer
If you press the stop button once, it moves the load profile immediately to the ramp down phase.
Avalanche will then play out the ramp down phase, and at the end of the ramp down phase, stop traffic and collect results.
NOTE: If after pressing the stop once you are seeing unsuccessfuls, check your ramp-down phase is providing enough time.
Ramp down must include enough time for the last SimUser to finish (i.e., if you are sending big objects and lots of them, long action lists, lots of think time, things may take more time) .
If the stop button is clicked twice, the test stops immediately (and no results are collected) without going to the ramp down time.