Printer FriendlyEmail Article Link

Why does the Terminate channel on the Abacus, wait so long before sending out any RTP traffic?

Answer

The cause of the delay may be due to the ‘Cut Through’ time being set to too long of a period under Configure/Channels/Terminate Subs/Answer/Cut Through.

Basically by setting the Cut Through Time to x, this is “the time that a terminate channel waits (after answering a call) before it sends a path confirmation signal to the originate channel”.   Please set this accordingly for your testing needs; the default is .8 seconds.


Product : Abacus,Voice,Path Confirmation,Automation,Analog,6.20,6.11 and below,SKINNY,SIP,RTP