Printer FriendlyEmail Article Link

Spirent TestCenter: Unable to save the complete Results into Database file with Spirent TestCenter due to an error “Save Results 1 failed with error: GetFilterWhereClause: 0 does not belong to the resultclass:InterestingStreamsResults“

Environment/Versions

Spirent TestCenter

Answer

Detail Description: After a test when try to save the results into a database file, the Spirent TestCenter throws the following Error

“Save Results 1 failed with error: GetFilterWhereClause: 0 does not belong to the resultclass:InterestingStreamsResults”
Also, the saved DB file does not have any contents as shown below
 
 
Root Cause and Resolution:
This is due a bad filter in the Interesting Stream Results.  
Please check the Interesting Stream Result filter and remove the filter where the filter field set to “N/A” as shown below
Remove the filter with name “CounterResultFilter1” Filter set to “ N/A”
Resave the Results

Product : Spirent TestCenter,L2-3,Spirent TestCenter,Results Reporter