Customer Service Center
Home
Knowledge Base
Contact Support
License Activation
|
Contact Support
|
License Activation
|
Spirent KB Article
Doc ID: FAQ12048
Printer Friendly
Email Article Link
Spirent TestCenter: How do I configure and utilize -> Port Traffic and Counters > Basic Traffic Results > Triggers on TestCenter?
Answer
Port Traffic and Counters > Basic Traffic Results > Triggers relates to the pattern definition option under capture and there are 8 triggers of 4 bytes each.
I mention you don’t have to start capture for these counters to increment but you do need to have one of the qualify/start/stop checkbox checked.
Attached document with screen shot and back to back port configuration.
Be aware of the the filter and mask used since due to each trigger counter is 4 bytes, the filter may span multiple triggers. Also if there are similar byte patterns in those 4 bytes you may see the count increment on one of the trigger counters.
Attachments
Attachment
triggers.tcc
Attachment Description
Three Triggers Back to Back Configuration
Attachment
triggers screenshot.docx
Attachment Description
Three Triggers Back to Back Configuration Screen shots
Version
3.0
Publish Date
2016-12-27
Categories
Product : Spirent TestCenter,Packet Captures
Related Articles