Email Article Link
Spirent TestCenter: Why is IMIX adding extra four bytes when testing with devices that have VLAN or MPLS?
Environment/Versions
Spirent TestCenter
IMIX
Answer
Detail Descriptions:
There is no additional four bytes added when Stream block frame Size configured with Fixed or other frame size option (except iMix) and with VLAN or MPLS added.
However, Stream block with iMix frame size with VLAN or MPLS always adding extra four bytes to the data when it received
Explanation/Resolution:
Fixed frame sizes and other frame sizes already included the VLAN or MPLS header and will not notice any different in the packet size.
The concern is only with IMIX.
iMix Frame size is mainly focused on the IP length and is where you set the length values.
Also displayed is the length of the packet if the default Ethernet frame is considered.
The default Ethernet does not include four byte VLAN or MPLS.
A default Ethernet frame can be one of two things.
1. ETH, IP, Padding FCS
64 byte is considered the minimum ethernet frame size, so padding is required if the IP length is not large enough to create a 64 byte frame.
2. ETH, IP, FCS
No padding required if IP length creates a frame that meet or exceeds the minimum ethernet frame size.
Since only the default Ethernet size is indicated in the IMIX editor, the user need to be aware of this when setting the IP length for VLAN or MPLS traffic.
VLAN Examples:
IP length is set for 40 bytes (Default Etherent size shows as 64 bytes)
ETH-VLAN-IP-Padding-FCS = 14+4+40+2+4
Since normally there would be 6 bytes of padding, adding a VLAN to this will still produce a 64 byte frame.
IP length is set for 46 bytes (Default Etherent size shows as 64 bytes)
ETH-VLAN-IP-FCS = 14+4+46+4
Although the default Ethernet size shows as 64 bytes, due to the VLAN, the actual length will be 68 bytes.