Printer FriendlyEmail Article Link

For the S-Band Blocker tests, why is the LTE interferer offset value set to 1.25 Mhz, when it should be at least 10Mhz apart from the PCS received signal?

Answer

 

This is a reporting issue. The way test case is implemented is that it hardcoded the center frequency of the interferer since they are fixed as per the VZW test plan.  The interferer (2Ghz) is set as per the test plan. The offset that appears in the test parameter is not used.
 
The current work around would be to change the offset test parameter (although it is not used to set the interferer) to valid values in the test suite. This should avoid any confusion. This way, when you generate the reports, the offset would have the correct values.
 

Product : Testdrive EVDO,TASKIT C2k