Printer FriendlyEmail Article Link

Spirent TestCenter: Streamblock error : Generator_3.SetStreamBlock code -10001 faultMsg Stream block (StreamBlock 60-4): Invalid input parameters: No more available parameter blocks.

Environment/Versions
STC 4.68:

It seems like Module(FX2-40G-Q5) tries to do path compression, but runs out of RIT memory. Hence it tries again to configure without path compression, there it fails due to not enough parameter blocks at FPGA.

Line 10605: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - error msgs: 7038 Stream block (StreamBlock 60-6): Invalid input parameters: No more available parameter blocks.
Line 10605: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - error msgs: 7038 Stream block (StreamBlock 60-6): Invalid input parameters: No more available parameter blocks.
Line 10606: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - error msgs: 7041 Invalid input parameters: Cannot find stream block id 23968 in database.
Line 10606: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - error msgs: 7041 Invalid input parameters: Cannot find stream block id 23968 in database.
Line 10608: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - Rpc manager received errors; 4 error msgs  SeqNum 7032 Msgr port //10.81.99.15/9/1 req Generator_3.SetStreamBlock code -10001 faultMsg Stream block (StreamBlock 60-4): Invalid input parameters: No more available parameter blocks.
Line 10608: 16/09/26 14:04:03.551 ERROR 1180     - fmwk.bll.core.rpc    - Rpc manager received errors; 4 error msgs  SeqNum 7032 Msgr port //10.81.99.15/9/1 req Generator_3.SetStreamBlock code -10001 faultMsg Stream block (StreamBlock 60-4): Invalid input parameters: No more available parameter blocks.
 
Answer
Issue Fixed in STC 4.70

CR: 01168975

Product : Windows GUI