Printer FriendlyEmail Article Link

Landslide: Why get an error message "There must be a local loop-back port starting pool address if number of nodes is filled out"in the Test Server Administration window?

Environment/Versions
  • Upgrade Landslide system from 11.0.0 to 11.5.0 GA
Answer
  • Open the Test Server Administration window, click configure button, enter the "Other Ethernet" and "Routing" tabs to setup IP addresses for each Ethernet interface and static routes
  • There is error message "There must be a local loop-back port starting pool address if number of nodes is filled out":
    • If you setup a value of "# of IPs" in Local Interface, but keeping "Pool IP" field blank. 
    • If you restore a test server backup, the "# of IPs" is filled with a 0.
  • To correct the error message, in the Test Server Administration>Configure, enter password, in the Main tab: 
    • Enter a value in "# of IPs" field and put a IP address in "Pool IP" field.
    • Or keep both fields empty.

Product : Landslide,TAS Manager,Landslide Client,Landslide