Landslide: Why get an error message "There must be a local loop-back port starting pool address if number of nodes is filled out"in the Test Server Administration window?
Environment/Versions
Upgrade Landslide system from 11.0.0 to 11.5.0 GA
Answer
Open the Test Server Administration window, click configure button, enter the "Other Ethernet" and "Routing" tabs to setup IP addresses for each Ethernet interface and static routes
There is error message "There must be a local loop-back port starting pool address if number of nodes is filled out":
If you setup a value of "# of IPs" in Local Interface, but keeping "Pool IP" field blank.
If you restore a test server backup, the "# of IPs" is filled with a 0.
To correct the error message, in the Test Server Administration>Configure, enter password, in the Main tab:
Enter a value in "# of IPs" field and put a IP address in "Pool IP" field.
Or keep both fields empty.