Spirent TestCenter: Why Spirent TestCenter reports an error "Interface IPv4 x on Device Host x has invalid Network Stack" on apply?
Environment/Versions
Spirent TestCenter
Unicast/Multicast MAC Addresses
Answer
Based on the error, the device configured with IPv4 encapsulation.
Error Detail:
Multicast MAC Address configured for Source MAC Address
ERROR messages from Logs:
1/16/2013 12:38:14 .7 Error Other Interface EthIIIf: Multicast MAC address is not allowed for emulated devices (Host x)
1/16/2013 12:38:14 .7 Info Other Interface IPv4 x on Device Host x has invalid Network Stack. Please see log for details
07:10:94:00:00:01 is a Multicast MAC Address
RESOLUTION:
Since this is a Layer 3 Unicast device, set the Ethernet Source Mac Address to a Unicast MAC Address.
Example 06:10:94:00:00:01