Vision Works Probe: Getting “CIR EXCEEDS LIMIT. RETRY LATER” error message when attempting an access on a VisionWorks Probe.
Environment/Versions
7502 all versions
7521
7522
7531
7561
Answer
When you get this error message, do the following:
Verify the probe has the TOTALCIR and TOTALKFPS setting set correctly. Follow
FAQ18026
.
If correct:
Find the comm log for the test that got the error message.
-or-
Telnet into the probe on port 7010.
If you telnet into the probe, issue :
act-user::super:ctag::super
rtrv-cond-tst:::ctag
Now, add up all the CIRs for all the entries. Remember that the TOTALCIR listed in RTRV-ATTR-EQPT output is across all ports and tests. So, if you have a 7531 with a TOTALCIR=1000 and you have a 900mbs test on port 1, you will only be able to test up to 100mbs on port 2.
In the following example of a 7521 (10G), 1180mbs are already taken up leaving 8820mbs available for any type of test on either port.
BRDVILBO-MOD1-QSCOPE 19-01-07 21:46:10
M EDR COMPLD
/* SPIRENT COMMUNICATIONS OF ROCKVILLE - COPYRIGHT (C) 2009-2017 */
/* TSN PORT VLAN PRI SRC_IP
CIR
KFPS DES_ADDR */
/* STATUS TYPE */
" 504 1
150.0
517 "
" TST-ETHDM-Y1731-PM "
" 635 2
150.0
497 "
" TST-SLA "
" 308 1 10.187.4.5
150.0
27 "
" TST-TWAMP-PM "
" 3 1 2278 10.187.4.3
20.0
47 "
" START-ADDR-LPBK "
" 2 2 1671 10.233.1.174
20.0
47 "
" START-ADDR-LPBK "
" 1 1 1670 10.233.1.170
20.0
47 "
" START-ADDR-LPBK "
" 6 2 2279 10.187.4.20
100.0
280 "
" START-TWAMP-SERVER "
" 5 1 2278 10.187.4.4
100.0
280 "
" START-TWAMP-SERVER "
" 4 2 2279 10.187.4.19
20.0
47 "
" START-ADDR-LPBK "
" 556 2
150.0
509 "
" TST-ETHDM-Y1731-PM "
" 616 2 10.187.4.21
150.0
27 "
" TST-TWAMP-PM "
" 585 1
150.0
502 "
" TST-SLA